Today, a new path for spam.
An email from my domain provider, passing on a contact to the admin address for my domain.
Misspelt .info domain, which if I reply to, they then have my email address.
Today, a new path for spam.
An email from my domain provider, passing on a contact to the admin address for my domain.
Misspelt .info domain, which if I reply to, they then have my email address.
There was a time when BT were world leaders in anything telecommunications
The UK seems to have an outdated idea of how fibre should be done, with the ONT where the fibre terminates being a fibre to copper converter, I think limited to 1Gb, also requires power. Then a copper patch lead to the router.
In Spain, the fibre terminates in an ONT, then a fibre patch lead to the router, any upgrades just mean changing the router, no silly speed caps on upload, it's symmetrical!, same speeds upload & download.
At this time they hit 85% of premises with fibre, 10Gb is available with 25Gb being trialled, all over the same, already installed fibre!
Come on BT/openreach, get back to being a world leader.
In the UK, domestic mains voltage used to be standardised at 240V +6% -6% so a range of 225.6V to 254.4V, in 1994 it was decided to harmonise with Europe at 230V, but with a fudge of -6% +10% so a range of 216.2V to 253V, but still nominally 240V. Europe changed from 220V to a nominal 230V.
247V at the top, 244V at the bottom, 0.5V per Div, Horizontal scale 30Sec per Div. Change of 2.5V over a matter of minutes, makes it hard to calibrate to 0.1V.
Tasmota energy monitoring has 2 commands to set voltage, VoltageSet<x> Calibrate voltage to a target value in V with x denoting which channel if more than 1. & VoltageCal<x> range of 1000 to 32000 (Default 1950) VoltageSet changes VoltageCal to suit the target Voltage.
Several ways to calibrate the voltage, using a calibrated voltmeter.
Buy a mains Voltage calibrator (several £k)
Use a pure sinewave UPS or inverter (several £100)
Setup an audio generator to 50Hz, plug into an audio amplifier, connect to a low voltage transformer used in reverse, rated so no distortion, rough guess for about 50W is a 20V secondary (used as primary) transformer, transformer rated about 100W, allows enough to power the device under test. (Several £10)(This appeals to the geek in me)
Last is setup a Voltmeter & the device, feed with mains Voltage, repeatedly set the voltage until near enough, this is what I did, but it rankles that its not as accurate as it could be, especially when you want to get several devices to agree with each other.